Reviewed and updated: August 2026
Calculate bars, linear feet, weight, and material cost for concrete slabs, footings, and walls. Enter your dimensions, rebar size, and spacing to get a complete rebar estimate with a live grid preview.
Results include a 10% lap splice and waste allowance. Always verify rebar size and spacing with your local building department or engineer before ordering.
Use this rebar calculator to estimate the number of bars, total linear footage, weight, and material cost for concrete slabs, footings, and walls. Enter your slab dimensions, rebar size, and on-center spacing to get a complete grid layout estimate.
Results include a 10% allowance for lap splices and waste. Always confirm rebar size, spacing, and placement requirements with your local building department or structural engineer before ordering material.
Rebar in a slab is placed in a two-directional grid: rows running the length of the slab and rows running the width. The number of bars in each direction depends on the slab dimension and the on-center spacing.
Bars in length direction = (slab width / spacing) + 1
Bars in width direction = (slab length / spacing) + 1
Each bar in the length direction runs the full length of the slab, and each bar in the width direction runs the full width. Add the total linear footage for both directions, then add 10% for lap splices (where bars overlap at joints) and waste from cut ends.
For example, a 20 x 20 foot slab with #4 rebar at 12-inch (1-foot) spacing:
Rebar is designated by number: the number corresponds to the diameter in eighths of an inch. #4 rebar is 4/8 = 1/2 inch in diameter. Each size has a specific weight per linear foot used to calculate total weight for supplier quotes.
| Bar Size | Diameter | Weight per Foot | Common Applications |
|---|---|---|---|
| #3 | 3/8 inch (0.375") | 0.376 lbs/ft | Walkways, driveways, light slabs, stirrups |
| #4 | 1/2 inch (0.500") | 0.668 lbs/ft | Residential slabs, footings, walls: most common |
| #5 | 5/8 inch (0.625") | 1.043 lbs/ft | Structural slabs, heavy footings, retaining walls |
| #6 | 3/4 inch (0.750") | 1.502 lbs/ft | Heavy structural applications, large footings |
| #7 | 7/8 inch (0.875") | 2.044 lbs/ft | Commercial structural elements |
| #8 | 1 inch (1.000") | 2.670 lbs/ft | Bridges, large commercial structures |
For most residential concrete work: slabs, footings, garage floors, patios: #4 rebar is the standard specification. #3 is acceptable for lightly loaded slabs like walkways and steps. #5 and larger are typically specified by an engineer for structural applications. Always use the size specified on your permit drawings, not a substitute based on availability.
Rebar spacing affects the strength and crack resistance of the concrete. Closer spacing distributes loads and controls cracking more effectively but increases material cost. The ACI 318 building code sets maximum spacing requirements based on slab thickness.
| Application | Typical Spacing | Notes |
|---|---|---|
| Residential driveway or patio (4-inch slab) | 18 inches OC | ACI maximum: 3x slab thickness or 18", whichever is less |
| Residential garage floor (4-inch slab) | 12 to 18 inches OC | 12" recommended for vehicle loads |
| Residential foundation wall | 12 inches OC vertical, 24" horizontal | Varies by wall height and soil pressure |
| Structural slab (6-inch) | 12 inches OC | Engineer specification required |
| High-load or structural footing | 6 to 12 inches OC | Engineer specification required |
The ACI 318 maximum spacing rule for slabs is the lesser of 3 times the slab thickness or 18 inches. For a standard 4-inch slab: 3 x 4 = 12 inches or 18 inches: the limit is 18 inches. For a 5-inch slab: 3 x 5 = 15 inches, so the maximum spacing is 15 inches. Tighter spacing is always acceptable: the ACI rule is a maximum, not a recommendation.
When a single bar is not long enough to span the full slab dimension, two bars are overlapped: this is called a lap splice. The minimum lap length is specified by ACI 318 and depends on bar size, concrete strength, and splice class. For practical estimating purposes:
The 10% waste factor used in this calculator accounts for lap splices at bar joints and material lost to end cuts. For very large slabs where many bars span full widths without splices, the actual waste may be slightly lower. For complex shapes with many short pieces, use 12 to 15% instead.
Rebar must be positioned at the correct depth within the concrete and must have adequate cover: the distance from the rebar surface to the nearest concrete face. Insufficient cover leads to corrosion, spalling, and structural failure over time.
| Application | Minimum Cover (ACI 318) | Notes |
|---|---|---|
| Concrete cast against earth (footings) | 3 inches | Permanent earth contact: highest cover requirement |
| Concrete exposed to weather (exterior slabs) | 1.5 inches (#5 and smaller) | Driveways, patios, exposed flatwork |
| Concrete exposed to weather (#6 and larger) | 2 inches | Larger bars in exposed conditions |
| Interior slabs not exposed to weather | 0.75 to 1.5 inches | Garage floors, basement slabs |
| Walls exposed to weather | 1.5 to 2 inches | Depends on bar size |
Rebar chairs (plastic or wire supports) hold the rebar at the correct height during the pour. Never place rebar directly on the ground or on rocks: the concrete will not encapsulate the bar properly and corrosion will begin from the bottom. In slabs, rebar is typically placed in the lower third of the slab depth: approximately 1.5 to 2 inches from the bottom: to control tensile cracking from bending loads.
Footings and slabs have different rebar configurations because they carry different types of loads.
Slabs are typically reinforced with a two-directional grid in the lower portion of the slab. The grid controls temperature and shrinkage cracking and provides tensile reinforcement against bending. Bar size and spacing depend on slab thickness and anticipated loads. Residential slabs typically use #4 at 12 to 18 inches on center in both directions.
Footings carry the concentrated loads from walls and columns and transfer them to the soil below. They use longitudinal bars running the length of the footing (typically 2 to 4 bars depending on footing width and load) with stirrups or ties at regular intervals for wider footings. Footing rebar is placed with 3 inches of cover from the bottom and sides. The number and size of longitudinal bars is typically specified by the engineer or local code.
Hardware stores sell rebar by the bar in 20-foot lengths. Steel suppliers and rebar distributors sell by the ton and are typically 20 to 40 percent less expensive for larger quantities. Use the weight output from this calculator when calling suppliers for bulk pricing. A ton of #4 rebar is approximately 2,994 linear feet, useful for quick back-of-envelope checks.
For the concrete needed alongside your rebar, use our concrete calculator. For a complete understanding of concrete costs, see our concrete cost guide. For total project budgeting, see our project cost estimation guide.